The product line of Dekraft (a brand of the Russian company Systemam Electric) has been replenished with the second generation of residual current circuit breakers DIF-103 4.5 kA NEW, designed to protect people from electric shock, wiring from fire, and electrical equipment from overvoltage
180 modifications allow you to select a residual current circuit breaker (RCBO) with a rated current from 6 to 63 A, leakage current of 10, 30, 100 and 300 mA and other parameters. Among the advantages of the Dekraft DIF-103 4.5kA NEW series RCBOs are the presence of installation instructions, characteristics and wiring diagrams on the device body, the implementation of visual notification when leakage current appears, and compatibility with components from circuit breakers of the VA-101 series.
The second generation of DIF-103 4.5 kA NEW residual current circuit breakers by Dekraft with RCD functions is part of the Energy Basic collection and is designed to protect people from electric shock when touching live parts that are live, or conductive parts that may be energized in case of insulation damage. The DIF-103 4.5 kA NEW series combines 180 devices with a breaking capacity of 4.5 kA, which makes it possible to select an RCBO residual current circuit breaker with a number of 1P+N or 3P+N poles, a width of 35.4 mm (2 modules) or 88.5 mm (5 modules), a rated current from 6 to 63 A, a leakage current of 10, 30, 100 and 300 mA, type AC or A and tripping curves C and D.
Among the competitive advantages of the DIF-103 4.5 kA NEW residual current circuit breakers are the installation instructions, characteristics and wiring diagrams printed on the device housings. This greatly simplifies the installation and maintenance of Dekraft machines. Another feature of the new products is the "R" button located on the front panel, which signals that the RCBO residual current circuit breaker has been activated in emergency mode when leakage current appears in the protected circuit. It allows you to visually identify a section of the circuit that has failed due to a malfunction and distinguish it from areas that have been manually disconnected.
A wide range of optional devices for DIF-103 4.5 kA NEW circuit breakers includes additional DC contacts, independent LP trips, SK signal contacts, RMK maximum voltage trips, RMN minimum voltage trips, as well as RMM maximum and minimum voltage trips. At the same time, all of them are installed on the left side of the residual current circuit breaker of the RCBO. It is worth noting that the accessories for the DIF-103 4.5kA NEW assault rifles are unified with the VA-101 series RCBOs, which speeds up the process of selecting components and significantly reduces the number of spare parts in the service warehouse.
Compliance with the requirements of the Technical Regulations of the Customs Union TR CU 004/2011 "On the Safety of Low-Voltage Equipment", TR CU 020/2011 "Electromagnetic Compatibility of Technical Equipment" and GOST IEC 61009-1 "Residual Current Operated Circuit Breakers with Built-in Overload Current Protection, Household and Similar Purposes" allows the use of DIF-103 4.5 kA NEW circuit breakers in floors, apartments, distribution rooms, ASUs and other shells. Each RCBO residual current circuit breaker of this series is produced in a case made of high-quality, durable plastic that does not support combustion, is designed for uninterrupted operation at temperatures from -40 to +60 °C and has a 5-year branded warranty.